HIMA F7131 Programmable controller
INQUIRE NOW
Products Name: HIMA F7131 Programmable controller
PRODUCT DESCRIPTION
HIMA Output Modules Overview
HIMA offers a variety of output modules as part of their safety-critical automation systems, such as HIMax and HIQuad. These modules are used to transmit control signals to field actuators like valves, relays, and contactors while maintaining the highest Safety Integrity Levels (SIL).
Product Detailed Description
Function:
Receives safety-related control signals from the HIMA safety controller.
Converts these signals into electrical signals suitable for driving field actuators.
Provides redundancy and diagnostic functions to ensure safe and reliable operation.
Available with different output types, such as relay outputs, transistor outputs, and analog outputs, to suit various actuator requirements.
Integrates fault detection mechanisms to detect and report faults within the module or in the field wiring.
Features:
Designed in accordance with the highest safety standards (e.g., SIL 3).
Redundant design for increased availability and fault tolerance.
Force-guided contacts (for relay outputs) to ensure a safe state.
Short-circuit and overload protection.
Line monitoring functions (e.g., wire break detection).
Modular design for easy expansion and replacement.
Hot-swapping capability (on some models) allows module replacement during system operation.
Product Parameters
As HIMA offers a range of output modules, the following are some general parameters. Always refer to the official datasheet for the specific model:
Output Type:
Relay outputs (e.g., normally open/normally closed contacts, single/double contacts).
Transistor outputs (e.g., PNP/NPN, 24 V DC).
Analog outputs (e.g., 4-20 mA, 0-10 V).
Number of Channels:
Different number of output channels per module (e.g., 4 channels, 8 channels).
Rated Voltage:
Varies depending on the output type and model (e.g., 24 V DC, 230 V AC).
Rated Current:
Varies depending on the output type and model (e.g., 2 A, 5 A).
Diagnostic Functions:
Short-circuit detection.
Wire break detection.
Open-circuit detection.
Response Time:
Response time of the output signal (e.g., a few milliseconds).
Degree of Protection (IP):
E.g., IP20.
Ambient Temperature:
Operating temperature range (e.g., -25 °C to +70 °C).
Safety Integrity Level (SIL):
Typically SIL 3.
Certifications:
Complies with relevant safety standards and certifications (e.g., TÜV).
Product Advantages
Maximum Safety:
Designed and certified to the highest Safety Integrity Levels (SIL), ensuring the safety of personnel and equipment.
High Reliability:
Redundant design and comprehensive diagnostic functions maximize system availability.
Fault Tolerance:
Redundancy ensures safe operation even in the event of component failure.
Comprehensive Diagnostics:
Integrated diagnostics allow for quick identification and reporting of faults, reducing downtime.
Flexibility:
Available with various output types and channel counts to suit different application requirements.
Easy Integration:
Modular design and hot-swapping capabilities simplify system integration and maintenance.
Precautions
Correct Selection:
Choose the appropriate output module based on the actuator type, voltage, current requirements, and the safety requirements of the application.
Correct Installation:
Install the module according to HIMA's installation manual, ensuring it is securely mounted and correctly wired.
Safety Circuit Design:
Integrate the output module into a safety circuit that complies with relevant safety standards.
Power Requirements:
Use a power supply that meets the specifications to ensure stable power to the output module.
Environmental Conditions:
Ensure the operating environment temperature and humidity are within the permissible range.
Regular Inspection and Testing:
Regularly check the operating status and diagnostic information of the output module, and perform functional tests to ensure proper operation.
Maintenance and Replacement:
Maintain and replace modules according to HIMA's recommendations.
Product Applications
HIMA output modules are widely used in various industrial sectors requiring the highest levels of safety and reliability, including:
Oil & Gas:
Safety Instrumented Systems (SIS) such as Emergency Shutdown (ESD) systems, High-Integrity Pressure Protection (HIPPS) systems, and Fire & Gas detection systems.
Chemical:
Process safety control and interlock systems.
Power Generation:
Boiler protection systems and turbine control systems.
Rail Transportation:
Signaling and safety systems.
Pharmaceutical:
Safety-critical process control.
Other Safety-Critical Applications:
Any automation system requiring compliance with high safety standards.
Shipping Port: China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Related products:
HIMA | Z7134/3334/C5/P2 | HIMA | F3105 (17.047) |
HIMA | Z7134/3334/C5/P2 | HIMA | F3108 17039 |
HIMA | 933236300-5 | HIMA | F3113 (17.033) |
HIMA | 933237100-5 | HIMA | F3113a (17.048) |
HIMA | 936217800-5 | HIMA | F3209 17012 |
HIMA | 936217900-5 | HIMA | F3211A (17.061) |
HIMA | 936217900-5 | HIMA | F3212A |
HIMA | 98-4862702 | HIMA | F3213A |
HIMA | 98-4862702 | HIMA | F3213A |
HIMA | BRH2106 | HIMA | F3215A |
HIMA | BV7044-15 | HIMA | F3226(17.007) |
HIMA | BV7044-30 | HIMA | F3316 (17.031) |
HIMA | F1101 | HIMA | F3328 (17.008) |
HIMA | F1107 17001 | HIMA | F3330 17013 |
HIMA | F1201 (17.040) | HIMA | F3334 |
HIMA | F1202 (17.046) | HIMA | F3403 (17.038) |
HIMA | F2101 (17.025) | HIMA | F3406a (17.049) |
HIMA | F2102 (17.045) | HIMA | F3410 (17.062) |
HIMA | F2103a (17.050) | HIMA | F3417A |
HIMA | F2108 (17.019) | HIMA | F3417a (17.034) |
E-mail: alex@fenoux.com
Tel.: +86 13338369201
Skype: +86 13338369201
WhatsApp: +86 13338369201
The winter solstice is Du 1 of the four solar terms of 20 Bai, and ...
Dec. 18 , 2020Let's first take a look at the literal meaning of the DCS system.
Dec. 24 , 2020